CI855K01 ABB 通信接口模塊數(shù)據(jù)最先出現(xiàn)在成都陽(yáng)光熹禾。
]]>CI855K01
用于傳輸或接收語(yǔ)音、圖像或其他數(shù)據(jù)的其他設(shè)備,包括用于在有線或無線網(wǎng)絡(luò)(例如局域網(wǎng)或廣域網(wǎng))中進(jìn)行通信的設(shè)備:-用于接收、轉(zhuǎn)換和傳輸或再生語(yǔ)音恩像成其他數(shù)握的機(jī)器,與括本換和路中設(shè)備海關(guān)種則是·85176200寸產(chǎn)品凈深度長(zhǎng)度65 mm產(chǎn)品海度203 mm產(chǎn)品凈157 mm品重:0.62 kg環(huán)境RoHS狀態(tài):遵循歐盟指令2011/65/歐盟WEEE類別小型設(shè)備(外部尺寸不超過50厘米)電池?cái)?shù)量:0
ABB機(jī)器人創(chuàng)建信號(hào)及關(guān)聯(lián)信號(hào)步驟車間ABB機(jī)器人較多,做改善或臨時(shí)增加信號(hào)需要對(duì)機(jī)器人的信號(hào)進(jìn)行配置,沒有標(biāo)準(zhǔn)化流程,過程不清晰。1、創(chuàng)建信號(hào)之前先到要?jiǎng)?chuàng)建的模塊里確認(rèn)地址有沒有被占用,創(chuàng)建組信號(hào)要查看組信號(hào)有沒有包含在內(nèi)的單個(gè)地址,創(chuàng)建單個(gè)信號(hào)要查看該信號(hào)有沒有被別的組信號(hào)所包含。2、選擇菜單,控制面板,配置系統(tǒng)參數(shù),signal, 顯示全部3、name:要?jiǎng)?chuàng)建的信號(hào)的名字;type of signal: 信號(hào)類型;assigned to device:要?jiǎng)?chuàng)建的信號(hào) 屬于那個(gè)模塊;device mapping:信號(hào)的地址。4、選擇菜單,控制面板,配置系統(tǒng)參數(shù),cross connection,顯示全部5、name:要?jiǎng)?chuàng)建的關(guān)聯(lián)信號(hào)的名稱;resultant: 關(guān)聯(lián)信號(hào)的結(jié)果;actor1:個(gè)條件;invert actor1:個(gè)條件是否取反;operator1:跟下 一個(gè)條件的關(guān)聯(lián)關(guān)系;actor2:第二個(gè)條件; invert actor2:第二個(gè)條件是否取反;operator2:跟下一個(gè)條件的關(guān)聯(lián)關(guān)系。
CI855K01
Manufacturer :ABB
Product Number :3BSE018106R1
Product model :C1855K01 MB 300 Dual Ethernet port
Transfer speed :10 megabits/SEC, 200 data sets/SEC
Maximum unit on the CEX bus :12
Connector :RJ-45 internal thread (8 pins)
Typical power consumption is 24 V. :150 mah
Operating temperature :55°C
Protection class: IP20 according to IEC 529 EN60529
Dimensions (H x W x D), approximately :18.5 cm x 5.9cm x 12.75cm
Weight :0.7 kg
Shipping weight :1.5 kg
Product Number :3BSE018106R1 ABB Model Name :C1855K01 Catalog Description :CI855K01 MB 300 Interface Long Description: Package includes :-CI855, MB 300 interface module -TP853, Baseboard Category Product Control System Product Control and Communication AC800M AC800M – Communication module CI855 MasterBus 300 interface C1855K01 MB 300 Interface Product Control System 800xA Controller AC800M Control software AC 800M control Software 40 Communication module Product control System 800XA controller AC 800M Hard AC 800M4.0 Communication module Product control system 800xA controller A800M Hardware AC 800M4.1 Communication module Product control system 800xA controller AC 800M. The package includes :- CI855, MB300 interface module TP853, substrate product type: Communication module order HS code :851762- telephone, including telephones for cellular networks or other wireless networks; Other devices used to transmit or receive sound, images or other data, including devices used to communicate over a wired or wireless network, such as a local or wide area network, other than transmitting or receiving devices under heading 84.43, 85,25, 85.27 or 85.28.
– Other equipment used to transmit or receive voice, images or other data, including equipment used to communicate in a wired or wireless network (such as a local area network or a wide area network) :- Machines used to receive, convert and transmit or reproduce voice data into other data sets, The customs type of equipment with this replacement and road is ·85176200 inch product Net depth Length 65 mm product sea degree 203 mm product net 157 mm product weight :0.62 kg Environmental RoHS status: comply with EU Directive 2011/65/ EU WEEE category Small equipment (external size does not exceed 50 cm) Number of batteries :0
There are many ABB robots in the workshop to create signals and associate signals. To improve or temporarily increase signals, the signals of robots need to be configured. There is no standardized process and the process is not clear. 1, before creating a signal, go to the module to be created to confirm whether the address is occupied, create a group signal to check whether the group signal is included in a single address, create a single signal to check whether the signal is included in other group signals. 2. Select Menu, Control Panel, and configure system parameters, signal, to display all 3. name: indicates the name of the signal to be created. type of signal; type of signal; assigned to device: Which module the signal to be created belongs to; device mapping: indicates the address of a signal. 4, select menu, Control panel, configure system parameters, cross connection, display all 5, name: to create the name of the associated signal; resultant: The result of the associated signal; actor1: a condition; invert actor1: whether a condition is inverted; operator1: association with the next condition; actor2: Second condition; invert actor2: whether the second condition is inverted; operator2: The relation to the next condition.
CI855K01
ABB | 3BSE013177R1 | ABB | 3AST000929R109 | ABB | CI858K01 |
ABB | CMA130 | ABB | 3ASC25H204 | ABB | 3BSE018135R1 |
ABB | 3DDE300410 | ABB | DAPU100 | ABB | KUC755AE105 |
ABB | SYN5201a-Z,V217 | ABB | 3ASC25H208 | ABB | 3BHB005243R0105 |
ABB | 3BHB006714R0217 | ABB | DATX100 | ABB | PFEA113-20 |
ABB | 5SHY3545L0009 | ABB | 3ASC25H214 | ABB | 3BSE028144R0020-1 |
ABB | GVC750BE101 | ABB | DATX130 | ABB | PM803F |
ABB | 3BHE009681R0101 | ABB | 3ASC25H216A | ABB | 3BDH000530R1 |
ABB | 3BHB013085R0001 | ABB | DATX132 | ABB | PM864AK01 |
ABB | 3BSE050090R20 | ABB | 3ASC25H219B | ABB | 3BSE018161R1 |
ABB | PFEA111-20 | ABB | DATX133 | ABB | 3BHE039203R0101 |
ABB | PM864AK01 | ABB | ICSE08B5 | ABB | GVC736CE101 |
ABB | 3BSE018161R1 | ABB | LDGRB-01 | ABB | CAI04 |
ABB | UFC762AE101 | ABB | 3BSE013177R1 | ABB | CI871K01 |
CI855K01 ABB 通信接口模塊數(shù)據(jù)最先出現(xiàn)在成都陽(yáng)光熹禾。
]]>